8199-00
Page 2 60707-117
MODEL HPS12000HE
Generator
Surge Watts* 12000
Continuous Watts* 10800
Volts 120/240
AMPs @ 240 Volts 45.0
AMPs @ 120 Volts 90.0
* Derate 10% for LP and 20% for NG
Engine Honda
Size 20 HP
Model GX620K1VXE2
Type - See Engine Shroud For Type
Fuel Capacity- 15 gal
Fuel Consumption
Gasoline 1.67 gal/hr
LP 2.2 gal/hr
NG 200 cu ft/hr
Starting System 12V Electric
Stop System Key
Complete Unit
Weight (dry) 274 LBS
Dimensions LxWxH 32 X 22 X 22
Fuel Gasoline/LP/NG
Oil Type SG SF/CC CD
Oil Weight (for general use) 10W -30
See engine manual for additional information
Oil Capacity 1.3 Quarts
Battery 12 Volt Group U1/235CCA
INTENDED USES
These engine generator sets have been designed primarily
for portable use. Both 120 and 240 Volt AC receptacles are
provided in the 'control panel' to plug in your loads (lights,
portable tools, and small appliances). These units are dual
wound generators, therefore the 120 Volt loads must be
equally split with 1/2 of the rated capacity available on each
of the two 120 Volt circuits. See unit capabilities for further
explanation.
These portable units require large quantities of fresh air for
cooling of both the engine and the generator. Fresh air is
drawn from both the engine end and the generator end and is
exhausted at the center of the unit. For safety, long life and
adequate performance, these units should never be run in
small compartments or enclosed areas without positive fresh
air flow.
RESTRICTED USES
DO NOT remove from the cradle assembly. Removal of the
generator from the cradle assembly may cause excessive
vibration and damage to the engine generator set.
DO NOT install and operate these portable generators in a
small compartment., i.e. generator compartment of vehicles,
motor homes or travel trailers. These compartments will not
allow enough free flow fresh air to reach the engine
generator set for cooling and will cause the unit to overheat,
damaging both the engine and the generator. Small
compartments will also develop hot spots where there is very
little air flow and may cause a fire.
DO NOT attempt to operate at 50 cycles. These units are
designed and governed to operate at 60 Cycles only.
SPECIFICATIONS
MODEL CSAHPS6000HE
Generator
Surge Watts* 6000
Continuous Watts* 5500
Volts 120/240
AMPs @ 240 Volts 22.9
AMPs @ 120 Volts 45.8
* Derate 10% for LP and 20% for NG
Engine Honda
Size 11 HP
Model GX340K1WE2
Type - See Engine Shroud For Type
Fuel Capacity- 4.5 gal
Fuel Consumption
Gasoline 1.0 gal/hr
LP 1.6 gal/hr
NG 160 cu ft/hr
Starting System Recoil/12V Electric
Stop System Key
Complete Unit
Weight (dry) 212 LBS
Dimensions LxWxH 30 X 22 X 22
Owner Must Provide
Fuel Gasoline/LP/NG
Oil Type SG SF/CC CD
Oil Weight (for general use) 10W -30
See engine manual for additional information
Oil Capacity 1.2 Quarts
Battery 12 Volt U1/235CCA
MODEL CSAHPS9000E
Generator
Surge Watts* 9000
Continuous Watts* 8000
Volts 120/240
AMPs @ 240 Volts 33.3
AMPs @ 120 Volts 66.7
* Derate 10% for LP and 20% for NG
Engine Briggs & Stratton
Size 16 HP
Model 303447
Type - See Engine Shroud For Type
Fuel Capacity- 4.5 gal
Fuel Consumption
Gasoline 1.3 gal/hr
LP 1.9 gal/hr
NG 180 cu ft/hr
Starting System Recoil/12V Electric
Stop System Key
Complete Unit
Weight (dry) 274 LBS
Dimensions LxWxH 32 X 22 X 22
Fuel Gasoline/LP/NG
Oil Type SE SG SF
Oil Weight See Engine Manual
specific information
Oil Capacity 1.75 Quarts
Battery 12 Volt U1/235CCA